The work area is continuously bathed with positive pressure ISO 5/Class 100 horizontal laminar flow air that has passed through a High Efficiency Particulate Air (HEPA) filter. The fan sucks the air through the filter pad where. Our Horizontal Laminar Flow Hood products are USP 797 compliant and designed for the handling of sterile products in an aseptic working environment. These devices only provide product protection. A laminar flow hood consists of a filter pad, a fan and a HEPA (High Efficiency Particulates Air) filter.

Horizontal laminar flow or vertical laminar flow “clean benches” are not biosafety cabinets these pieces of equipment discharge HEPA-filtered air from the back of the cabinet across the work surface toward the user, and they may expose the user to potentially hazardous materials. Vertical flow hoods, on the other hand, provide significant protection to the user and the cell culture. The flow can be horizontal, blowing parallel to the work surface, or it can be vertical, blowing from the top of the cabinet onto the work surface.ĭepending on its design, a horizontal flow hood provides protection to the culture (if the air flowing towards the user) or to the user (if the air is drawn in through the front of the cabinet by negative air pressure inside). A laminar flow hood plays a crucial role in maintaining a sterile environment for various stages of the cultivation process, such as agar work, inoculations. A horizontal flow hood require additional depth to accommodate the rear-mounted blower and make-up air space needed to feed the system. Fluorescent lampĪ fluorescent lamp lit up the cabinet’s interior to carry out the work smoothly.Laminar flow hoods protect the working environment from dust and other airborn contaminants by maintaining a constant, unidirectional flow of HEPA-filtered air over the work area. The HEPA filter, installed in the rear of the work zone, draws ambient room air from behind the horizontal flow hood laterally across the work area toward the front exit sash. Air is taken through this HEPA filtration system and exhausted across the work surface. This set up id designed to create a particle-free working environment and provide product protection from contamination. Turn the UV lamp on 15 minutes before starting your work. Laminar flow hoods create this unidirectional flow of air with one or more HEPA filters and pre-filters.
Laminar flow hood filters skin#
The UV rays can be harmful if they contact the human skin and can cause skin cancer. Regarding the hood cleanliness performance, most popular laminar flow hoods are in two classes: ISO 4 (Class 10) and ISO 5 (class 100). Ultraviolet rays have germicidal effects that sterile the chamber because of their germicidal effects. HEPA filters remove all the microbes providing sterile air flowing in the workstation. The fan sucks that air which is then passed through the HEPA filters. The air first passes through the filter pad, which traps the significant contaminant. There are one fan and two filters present in the laminar flow hood Pre-filter or filter pad or HEPA (High-Efficiency Particulate Air) filter Sterile your hand and working material with alcohol before entering them into the chamber. This type of glass shield has two openings wide enough to put the worker’s hand in the chamber. You can open it entirely, but it is recommended to open it half to protect the worker.